Wood Fiber Cement Bonded Acoustical Ceiling Tiles are 20 mm thick acoustic ceiling tiles made from pine wood fibers bonded with cementitious material. Their porous and textured surface helps absorb and diffuse sound, reducing echo and improving sound clarity in auditoriums, halls, studios, conference rooms, and interior ceiling areas.

The tiles are installed on a 15 mm black grooved silhouette ceiling grid with a calculated air gap behind the panels for better acoustic performance. The system also provides thermal insulation, moisture resistance, mold and pest resistance, fire resistance, and a clean spray-painted decorative finish.

Technical Documents

Your enquiry is handled confidentially. No spam.

Product Specifications

Wood Fiber Cement Bonded Acoustical Ceiling Tiles

Product Overview

Wood Fiber Cement Bonded Acoustical Ceiling Tiles are used for acoustic ceiling treatment, decorative ceiling finish, and thermal insulation in auditoriums, halls, studios, conference rooms, corridors, and interior ceiling areas.

The system uses 20 mm thick wood fiber cement bonded acoustical tiles made from pine wood fibers bonded with cementitious material. The porous and textured surface helps absorb and diffuse sound, especially in mid and high frequency ranges, while improving interior aesthetics.

The tiles are installed on a 15 mm black grooved silhouette ceiling grid system with calculated air gap behind the tiles to improve acoustic performance.

Purpose

The purpose of this ceiling system is to reduce noise, improve sound clarity, and provide a decorative acoustic ceiling finish.

It helps in:

  • Reducing reverberation and echo
  • Improving speech and sound clarity
  • Diffusing sound waves to avoid sound dead zones
  • Supporting acoustic ceiling treatment with air gap
  • Providing thermal insulation
  • Enhancing ceiling aesthetics with textured finish

Installation Layer / Actual Process

1. Base Ceiling / Structural Soffit

The work starts from the existing RCC slab or structural soffit. Ceiling levels, grid layout, suspension points, and service openings are marked as per approved architectural drawings and EIC instructions.

2. Suspension System

The suspension system is fixed to the structural soffit to support the ceiling grid.

  • Suspension spacing: Maximum 1200 mm c/c
  • First and last suspension point: Maximum 450 mm from adjacent wall

3. Silhouette Grid Installation

A 15 mm black grooved silhouette grid system is installed using main runners and cross tees.

  • Main runner spacing: 1200 mm c/c
  • 1200 mm cross tees fixed at 600 mm c/c
  • 600 mm cross tees used to form 600 mm x 600 mm modules
  • Cut cross tees longer than 600 mm to be independently supported

4. Perimeter Trim Fixing

Wall angles are fixed around the perimeter for proper edge support and alignment.

  • Wall angle size: 3000 mm x 19 mm x 19 mm
  • Wall angle fixing: Maximum 450 mm c/c

5. Air Gap Provision

A calculated air gap is maintained behind the acoustical tiles as per acoustic design requirement. This helps improve sound absorption, control reflections, and reduce reverberation.

6. Tile Placement & Finish

20 mm thick wood fiber cement bonded tiles are placed accurately on the grid. Panels shall be spray painted in the approved colour for final finish and protection against moisture, dust, and dirt.

Key Features

  • 20 mm thick wood fiber cement bonded acoustical tiles
  • Porous surface for sound absorption
  • Textured finish for sound diffusion
  • Helps reduce echo and reverberation
  • Supports mid and high frequency absorption
  • Improves acoustic clarity in large spaces
  • Provides thermal insulation
  • Moisture, mold, and pest resistant
  • Fire resistant ceiling tile system
  • 15 mm black grooved silhouette grid
  • Spray-painted finish in approved colour
  • Suitable for decorative acoustic ceiling treatment

Technical Information

  • Product Type: Wood Fiber Cement Bonded Acoustical Ceiling Tile System
  • Tile Thickness: 20 mm
  • Material: Pine wood fibers bonded with cementitious material
  • Grid Type: 15 mm black grooved silhouette ceiling grid
  • Module Size: 600 mm x 600 mm
  • Main Runner Spacing: 1200 mm c/c
  • Suspension Spacing: Maximum 1200 mm c/c
  • First / Last Suspension Distance: Maximum 450 mm from adjacent wall
  • Cross Tee Spacing: 1200 mm cross tees at 600 mm c/c
  • Perimeter Wall Angle: 3000 mm x 19 mm x 19 mm
  • Wall Angle Fixing: Maximum 450 mm c/c
  • Fire Resistance Standard: As per BS 476
  • Light Reflectance: More than 75%
  • Finish: Spray paint in approved colour
  • Acoustic Requirement: Calculated air gap as per acoustic design
  • Installation: As per approved architectural drawings and EIC instructions

Scope of Work

The scope includes providing and fixing of 20 mm thick wood fiber cement bonded acoustical ceiling tiles with 15 mm black grooved silhouette grid system.

The work includes marking, level setting, suspension fixing, main runner installation, cross tee fixing, perimeter trim fixing, air gap provision, tile placement, spray painting, final finishing, alignment checking, and cleaning.

All tools, machinery, manpower, staging, scaffolding, consumables, suspension accessories, grid components, trims, tiles, paint, and installation materials shall be included. The work shall be executed by skilled labour at all required heights as per approved drawings, acoustic requirements, safety norms, and Engineer-in-Charge instructions.

Quality & Safety Requirements

  • Tiles and grid shall be as per approved specification
  • Ceiling levels shall match approved architectural drawings
  • Grid system shall be properly aligned, levelled, and securely fixed
  • Suspension points shall be fixed properly to the structural soffit
  • Air gap shall be maintained as per acoustic design
  • Tiles shall be placed without cracks, stains, or uneven joints
  • Spray paint finish shall be uniform and clean
  • Perimeter trims shall be fixed neatly at required spacing
  • Work at height shall follow all safety protocols
  • Final installation shall be completed as per EIC instructions

Recommended Finish

Panels shall be spray painted in approved colour as per architectural design, interior theme, and Engineer-in-Charge instructions.

B2B Quote Request

Enquire About This Product

Enquiring about: Wood Fiber Cement Bonded Acoustical Ceiling Tiles

Confidential. We never share your information.

Project Consultation

Start Your Auditorium Project

Speak directly with our turnkey engineering team for acoustic design, stage lighting specifications, BOQ estimation, and turnkey delivery.

Auditorium Works delivers turnkey auditorium planning, consulting, engineering, and execution. We integrate acoustics, AV systems, stage lighting, machinery, seating, and interiors into one coordinated delivery path from concept to commissioning.

Auditorium Works project atmosphere